Construction and detail


Contur 600/625


Suspension system
The spacer bars shall be fixed max. 100 mm from the hangers. At joints of main T-runners, hangers shall be fixed. The suspension hanger must be fixed to the main runner at 1500 mm centres and not less than 100 mm from the wall angle.

Components
Suspension grid, hangers etc. are made from galvanised steel. The exposed sections are painted in CMC 001 Global white (equivalent to NCS 0902 G48Y).


MAINRUNNER
SPACER BAR
SHADOW EDGE TRIM WALL ANGLE
Part no. 85030
W x L x H 24 x 3600 x 38
Part no. 8260013
L 600
Part no. 8269913
L 300
Part no. 1459
W x L x H 10+24x3050x12+19
Part no. 1438
W x L x H 19 x 3050 x 32
ADJUSTABLE HANGERS
Part no. Length
11022 120- 200
11030-99 200- 270
11030 250- 320
11040 250- 440
11070 380- 690
11090 500- 940
11120 750- 1210
11150 750- 1440
11200 1000- 1940
*

Cross section 1, Contur 600, with painted fix frieze of gypsum board screw-fixed on 35 mm T-profile.

Drawing no.: 10.2.001
 

Cross section 2, Contur 600, with painted fix frieze of gypsum board screw-fixed on 35 mm T-profile.

Drawing no.: 10.2.002


Longitudinal section, Contur 600, with painted fix frieze of gypsum board screw-fixed on 35 mm T-profile.

Drawing no. 10.2.003 

Longitudinal section, Contur 600, with shadow edge trim.

Drawing no. 10.2.004


Cross section 3, Contur 600, with shadow edge trim.

Drawing no. 10.2.005

Cross section 4, Contur 600, with shadow edge trim.

Drawing no. 10.2.006