| Wall rail 5110 is secured to the wall for every 400 mm 12 mm above the finished ceiling level. | |
| Girder sections are installed for every 600 mm by pushing the sections into the wall panel and slinging them from the ceiling at a cc-distance of 1500 mm. Subsequently a distance retainer is installed on top of the cross-sections next to the slings. | |
Frieze profiles
Cross-section (6422069) is installed crosswise of the grid section as a demarcation between the acoustic ceiling and frieze solution. Subsequently cross-section (6442069) is cut and installed into the grid section and into the wall panel for every 600 mm. If the frieze width exceeds 300 mm, the cross-sections are installed for every 300 mm.
| |
Tectopanels, which have bevelled edges, or building boards for filling with edge rail KS13 are used as frieze tiles. Both boardtypes are screwed into the wall rail and cross-section. Check the angle and perforation against opposite friezes, which is important on account of the subsequent installation of elements in the acoustic section.
| |
| Drawing no. 10.2.001
|
| Drawing no. 10.2.002
|
| Fixed frieze of Tectopanel on system 650 up against the milled Contur edge. |
| Fixed frieze of Tectopanel on system 650 up against the cam fitting edge on Contur. |
|
|
|
Drawing no. 10.2.003
|
| Drawing no. 10.2.009
|
| Fixed frieze of Tectopanel on system 650 up against the end edge of Contur. |
| Fixed frieze of 12.5 mm building board with KS13 edge rail on system 650. |